1) Background
The IAEA identified through the comprehensive safety assessment of VVER-1000 reactors that the existing DC supply, in particular batteries to be a safety issue because of the following:
Search
Contract information field: Programme
Contract information field: Country
Contract information field: Budget year
Contract information field: Status
Contract information field: Contractor
- Alstom (2) Apply Alstom filter
- Carl Zeiss (1) Apply Carl Zeiss filter
- Deutsche Exide StanBy (1) Apply Deutsche Exide StanBy filter
- Lloyd Instruments (1) Apply Lloyd Instruments filter
- Mitsui Babcock (1) Apply Mitsui Babcock filter
- Roeii Amsier (1) Apply Roeii Amsier filter
- VHB Germany (1) Apply VHB Germany filter
Contract information field: Sector
Contract information field: Types of activities
Contract information field: Partner (Beneficiary)
Contract information field: Installation Types
Contract information field: Nuclear Power Plant
- (-) Remove Aktau filter Aktau (6)
- (-) Remove Khmelnitsky filter Khmelnitsky (2)
- Zaporozhye (19) Apply Zaporozhye filter
- South Ukraine (17) Apply South Ukraine filter
- Beloyarsk (9) Apply Beloyarsk filter
- Balakovo (7) Apply Balakovo filter
- Kalinin (7) Apply Kalinin filter
- Rovno (5) Apply Rovno filter
- Smolensk (4) Apply Smolensk filter
- Leningrad (Sosnovy Bor) (3) Apply Leningrad (Sosnovy Bor) filter
- Bilibino (1) Apply Bilibino filter
- Kola (1) Apply Kola filter
Contract information field: Nature
Contract information field: Method of procurement
Background
Objectives
The objective of this project was to provide to the End User, that is the nuclear power plant BN-350 (Aktau, Kazakhstan), with several equipment for the metallurgic analysis, mainly devoted (but not limited) to destructive and non-destructive testing (NDT).
Objectives
The objective of this project was to provide to the End User, that is the nuclear power plant BN-350 (Aktau, Kazakhstan), with several equipment for the metallurgic analysis, mainly devoted (but not limited) to destructive and non-destructive testing (NDT).
Objectives
The objective of this project was to provide to the End User, that is the nuclear power plant BN-350 (Aktau, Kazakhstan), with several equipment for the metallurgic analysis, mainly devoted (but not limited) to destructive and non-destructive testing (NDT).
Objectives
Objectives
Objectives
In the framework of the “Tacis Nuclear Safety Programme”, it was decided to improve the passive fire protection facilities of the BN-350 NPP (fast breeder) in Aktau, Kazakhstan. The project was divided into three lots: